2007 FL GHC ICC Tezak Kilcollins

Information about 2007 FL GHC ICC Tezak Kilcollins

Published on October 5, 2007

Author: Jolene

Source: authorstream.com

Content

Overall Goal of the IS-STM:  Overall Goal of the IS-STM Develop a standard that provides a very high degree of life-safety protection from extreme storm events for Residential and Community Shelters Question: What is your performance expectation of a storm shelter? Presentation Agenda:  Presentation Agenda The Purpose and Scope of IS-STM Storm Shelter Standard (ICC-500) Highlights of the Design Provisions Structural Systems Building Envelope Operational & Human Features Schedule / Status of the Standard Questions / Additional Discussions ICC/NSSA Storm Shelter Standard:  ICC/NSSA Storm Shelter Standard Collaborative effort International Code Council National Storm Shelter Association Federal Emergency Management Agency Begun in spring 2003 Standard anticipated in January 2008 Purpose of the ICC-500:  Purpose of the ICC-500 Establish minimum requirements to safeguard the public health, safety, and general welfare relative to the design, construction, installation, repair, operation and maintenance of storm shelters constructed for refuge from high winds associated with tornadoes and hurricanes. This standard is intended for adoption by government agencies and organizations setting model codes to achieve uniformity in the technical design criteria in building codes and other regulations. To protect occupants during high wind events:  Enterprise, AL March 2007 8 killed while taking refuge from a tornado No shelter in the school To protect occupants during high wind events To protect occupants during high wind events:  To protect occupants during high wind events Arcadia, FL Hurricane Charley, 2004 1,000+ people evacuated during storm To protect occupants during high wind events:  To protect occupants during high wind events Patterson, LA Hurricane Andrew, 1992 Designated shelter, luckily not used Scope of the ICC-500:  Scope of the ICC-500 This standard applies to design, construction, installation, inspection, and operation of storm shelters constructed independently or constructed as safe rooms within a building for the purpose of providing safe refuge from storms that provide high winds, such as tornados or hurricanes. Residential and Commercial Includes Considerations for Architectural Structural Mechanical Electrical Plumbing Other Chapters of the ICC-500:  Chapters of the ICC-500 Chapter 1 – Application and Administration Chapter 2 – Definitions Chapter 3 – Structural Design Criteria Chapter 4 – Siting Chapter 5 – Occupancy, Means of Egress, and Accessibility Chapter 6 – Fire Safety Chapter 7 – Shelter Essential Features and Accessories Chapter 8 – Test Methods for Impact and Pressure Testing Commentary Highlights of the Design Provisions:  Highlights of the Design Provisions Structural and Envelope Wind Speeds & Structural Loads:  Wind Speeds & Structural Loads Apply to all shelter types Community or Residential Large or Small Wind Speed Maps and Shelter Design Wind Speeds / Wind Loads Design methods Design Parameters Windborne Debris Other Loads and Considerations Application of Pressures and Debris Requirements:  Application of Pressures and Debris Requirements Wind Pressure Criteria Apply to all MWFRS per ASCE 7 Enclosure classification has different requirements Apply to all C&C per ASCE 7 Including all doors and protection devices Debris Impact Criteria Apply to all exterior surfaces providing protection for shelter occupants Shelter Design Wind Speeds:  Considered probabilistic maps Considered historical data and maps Proposing separate maps and design criteria (including debris) for Tornado shelters Hurricane shelters Theme throughout IS-STM Standard Shelter Design Wind Speeds Slide14:  Peak Gusts over Land by Hurricane Category (after Vickery et al, 2000), and Enhanced Fujita Scale (Wind Science and Engineering Center, 2006) * Original Fastest ¼ mph wind speeds proposed for Fujita Scale Slide15:  3-sec peak gust 33’ above grade Exposure C ASCE 7 BASIC WIND SPEED MAP (Fig. 6-1) Slide16:  ICC-500 Hurricane Shelter Design Wind Speeds Slide17:  Hurricane Shelter Design Wind Speeds 160 Slide18:  Cat 5 – Hurricane Camille Strong Cat 4 – Hurricane Andrew Weak Cat 4 Hurricane Charley F3 tornado Slide19:  FEMA 361 Shelter Design Wind Speeds Slide20:  ICC-500 Tornado Shelter Design Wind Speeds Calculation of Wind Loads (Use ASCE 7, and adjust as proposed):  Calculation of Wind Loads (Use ASCE 7, and adjust as proposed) Velocity Pressure (psf): q = 0.00256 KzKztKdV2I Kz = Velocity Pressure Exposure Coefficient Kzt = Topographic Factor Kd = Wind Directionality Factor V = Design Wind Speed I = Importance Factor Kz Velocity Pressure Coefficient and Site Exposure:  Kz Velocity Pressure Coefficient and Site Exposure Velocity profiles remain unchanged, but selection of exposure categories is modified Use Exposure C for Tornado Shelters – MWFRS and C&C Use Exposure C Hurricane Shelters – MWFRS and C&C Exception: Exposure B is permitted in cases where this roughness will very clearly remain in place even after an intense hurricane (MWFRS only) Summary of Design Coefficients Differences:  Summary of Design Coefficients Differences ASCE 7-02 Kz based on exp B or C Kd = 0.85 V = 2% annual prob (64% chance in 50 years) I = 1.15 Draft ICC-500 Standard Kz exp C, w/ limited B Kd = 1.0 V = 0.01% annual prob (0.5% chance in 50 years) I = 1.0 Internal Pressure:  Internal Pressure For Tornado shelters – APC must be considered Use GCpi = +/- 0.18 + APC contribution Use GCpi = +/- 0.18 + design for venting Use GCpi = +/- 0.55 For Hurricane shelters – no APC Use GCpi = +/- 0.18 or +/- 0.55 per ASCE and largest opening requirement In FEMA 361, must use GCpi = +/- 0.55 Load Factor:  Load Factor Strength design. Use the ASCE 7 load combinations with the following modifications: In load combination 3, replace 0.8W with 0.5W In load combinations 4 and 6, replace 1.6W with 1.0W Exception 1 shall not apply In FEMA 361, a 1.2W was used in load combination 6 Allowable stress design. Use the ASCE 7 load combinations with the following modifications: In load combinations 5, 6, and 7 replace W with 0.6W In FEMA 361, a W was used – there was no reduction Design Pressure Comparison Example - Ft. Lauderdale:  Design Pressure Comparison Example - Ft. Lauderdale Proposed Design Pressures are 44% larger than ASCE 7 Proposed Design Pressures are 13% lower than EHPA (using recommended wind speed of ASCE 7 + 40 mph) Percentages will vary with location along the coast Windborne Debris:  Windborne Debris Much new research recently published and underway Aerodynamics – wind tunnel and analytical and numerical models indicate that missiles travel at higher wind speeds than previously assumed Post-disaster debris information gathered to help develop/validate new debris flight/trajectory models ICC-500 Tornado Missile:  ICC-500 Tornado Missile Representative missile = 15 lb 2x4 Horizontal missile speeds (see table) Current FEMA 361 missile for all zones: 15 lb 2x4 Horizontal speed = 100 mph Vertical speed = 67 mph ICC-500 Hurricane Missile:  ICC-500 Hurricane Missile Representative missile = 9 lb 2x4 Horizontal missile speed 0.4 x V V = peak gust wind speed See table Vertical missile speed 0.1 x V Current FBC large missile: 9 lb 2x4 Horizontal speed = 34 mph Protection of Building Envelope:  Protection of Building Envelope Walls and roof systems must be impact resistant Roofs cannot have loose-laid roof coverings Openings required to be debris impact resistant or have impact resistant coverings (opening protectives) These requirements are consistent with FEMA 361 Doors and opening protectives:  Doors and opening protectives Must resist design wind pressures Must resist design forces from representative windborne debris No minimum requirements for hinges or latches – must past tests FEMA 320 and 361 – must have 3 latches and 3 hinges Door Systems:  Door Systems Shelter doors will be opened during the storm, for numerous reasons including late arrivals investigating damage moving between shelter areas people wanting to smoke etc. - human nature Opening Protectives ( ie., Window Protection Systems) :  Will systems requiring operation or installation work as planned? Do Shelter operators have the knowledge time materials, tools, keys to install/operate hurricane protections systems? Opening Protectives ( ie., Window Protection Systems) Opening Protectives:  Opening Protectives Tornado Shelters Readily available Readily installed / closed All components attached to protection Hurricane Shelters Allowed to be stored and installed over time Must resist pressures and debris impact Complete Testing Protocol for Pressure and Debris Impacts:  Complete Testing Protocol for Pressure and Debris Impacts Complete protocol for pressure testing of walls, roofs, and opening protectives Complete protocol for debris impact testing of walls, roofs, and opening protectives Design Provisions:  Design Provisions Flood Considerations Flood Hazards - Community Shelters:  Flood Hazards - Community Shelters The shelter floor shall be elevated above the highest elevation determined from: Local floodplain management requirements 100 year flood elevation + 2 ft (BFE+2) 500 year flood elevation, when determined Maximum inundation elevation from a Category 5 hurricane in areas subject to storm surge Note: Appropriate rainfall flooding should also be considered Flood Hazards – Residential Shelters:  Flood Hazards – Residential Shelters The shelter floor shall be elevated above the highest elevation determined from: Local floodplain management requirements One foot above the flood elevation corresponding to the highest recorded elevation if the area is not in a mapped special flood hazard area or in a non-participating community (with respect to the NFIP). Note: Appropriate rainfall flooding should also be considered Rain Loads for Hurricane Shelters:  Rain Loads for Hurricane Shelters Special Precautions should be taken: Heavy rains can last several days Pay special attention to design of secondary drainage Drains may become clogged by debris or wind-induced movement of roof gravel Must carefully consider ponding phenomena This was not addressed in FEMA 361 Identification of Design Parameters:  Identification of Design Parameters Specified in Section 106 and 107 Addresses the need for special inspections Requirements for signage and labeling Requirements for the identification of design parameters on building plans Provides minimum square footage requirements for occupants Design Provisions:  Design Provisions Operational and Human Factors Use and Occupancy:  Use and Occupancy Normal use occupancy code requirements apply, unless otherwise noted Dedicated single-use shelters are “assembly” occupancy Shelter definition: A building, structure, or portion(s) thereof, constructed in accordance with this standard, designated for use during a severe storm event. Use and Occupancy:  Use and Occupancy Shelter requirements separated into two types: Tornado Hurricane Shelter Types subdivided: Large, 51 or more occupants Small, 50 or less occupants Exception: Residential and One & Two Family Dwellings (16 or less occupants) Use and Occupancy:  Use and Occupancy Number of Egress Doors Determined by normal use as required by applicable code “Assembly” use shall apply to single-use shelters Doors must swing in direction of egress An emergency escape opening is required where two or fewer doors (direction of swing is inward to shelter space) egress to the outside of the shelter Exception for doorways protected from accumulation of debris Use and Occupancy:  Use and Occupancy Occupant density based upon “net usable floor area” Net usable is space that can actually be occupied by a person Number of standing, seated, wheelchair and bedridden spaces to be determined by applicable authority Shelters shall be sized for at least one wheelchair space per 200 occupants Design occupancy period: Tornado @ 2 hours Hurricane @ 24 hours Use and Occupancy:  Use and Occupancy Minimum net usable floor area per occupant, Community Shelters: Tornado Standing or seated = 5 sq.ft. Wheelchair = 10 sq.ft. Bedridden = 30 sq.ft. Hurricane Standing or seated = 20 sq.ft. Wheel Chair = 20 sq.ft. Bedridden = 40 sq.ft. Generally consistent with FEMA 361 Use and Occupancy:  Use and Occupancy Minimum net usable floor area per occupant, Residential Shelters: Tornado 1&2 Family Dwellings = 3 sq.ft. All other residential - Standing or seated = 5 sq.ft. Wheelchair = 10 sq.ft. Bedridden = 30 sq.ft. Hurricane 1&2 Family Dwellings = 7 sq.ft. All other residential - Standing or seated = 10 sq.ft. Wheel Chair = 10 sq.ft. Bedridden = 40 sq.ft. Generally consistent with FEMA 320, but more detailed Operational and Functional Considerations:  Operational and Functional Considerations IS-STM sets requirements for: Ventilation Back-up/emergency power Emergency lighting ADA compliance Fire barrier ratings Toilets and handwashing fixtures On-site potable water Supplies (such as first-aid kits) Generally codifies the criteria from FEMA 361 Does not address operations and management plans Essential Features & Accessories:  Essential Features & Accessories Hurricane Shelters Natural Ventilation required Two options; above- and below-ground Outside air intakes to be located 10 ft from noxious contaminant sources Exhaust or intake openings to be protected Mechanical ventilation required consistent with emergency power system Essential Features & Accessories:  Essential Features & Accessories Hurricane Shelters Emergency power system required; system to support occupied spaces, critical support areas & systems: Life safety systems Standby lighting; avg=10 f.c. Standby branch wall circuits Mechanical ventilation circuits Permanent-installed standby gen-sets not required Standby gen-set(s) to be independent of off-site utilities All components of emergency power system to be protected from design event; including temporary gen-set Essential Features & Accessories:  Essential Features & Accessories Hurricane Shelters Standby gen-set to operate continuously for 24 Hours Standby & emergency power system’s access route to be protected from design event Emergency lighting req’d; avg=1 f.c. Exceptions for small shelters and 1&2 family dwellings; one flashlight per 10 occupants Essential Features & Accessories:  Essential Features & Accessories Hurricane Shelters Standby gen-set to operate continuously for 24 Hours Standby & emergency power system’s access route to be protected from design event Emergency lighting req’d; avg=1 f.c. Exceptions for small shelters and 1&2 family dwellings; one flashlight per 10 occupants Use and Occupancy:  Use and Occupancy Shelters shall be provided with an accessible route (ANSI A117.1) Fire Extinguisher req’d within shelter areas Exception for 1&2 Family Dwellings Use and Occupancy:  Use and Occupancy Two-hour fire barrier separation req’d between shelter space and other building areas Includes penetrations and openings Exception for 1&2 Family Dwellings Exterior walls of storm shelters to be constructed with fire-resistance req’d by applicable code Essential Features & Accessories:  Essential Features & Accessories Hurricane Shelters Plumbing/Water Small shelter: No reqm’ts for potable or waste water Large Shelter: One gallon potable water/occupant Large Shelter: 1 1/2 gallons waste water/occupant Temporary or on-demand resources acceptable Essential Features & Accessories:  Essential Features & Accessories Hurricane Shelters Plumbing/Sanitation Small shelter: One toilet Large Shelter: One toilet/50 occupants Small Shelter: Handwashing facilities not req’d Large Shelter: One Handwashing facility/100 occupants Temporary fixtures acceptable Exceptions for 1&2 Family Dwellings Essential Features & Accessories:  Essential Features & Accessories Hurricane Shelters First-aid kit req’d for small and large shelters Exception for 1&2 Family Dwellings Essential Features & Accessories:  Essential Features & Accessories Signage req’d for both Tornado and Hurricane Shelters, Large & Small Interior signage must direct occupants to shelter areas Signage req’d on inside of shelter area(s) Floor Plan sign req’d in facility manager’s office, inside shelter area & at exits Exception for 1&2 Family Dwellings Public Comment Phase for ICC-500:  Public Comment Phase for ICC-500 1st Public Comment Draft Posted for public comment - November 10, 2006 Public comment closed – December 26, 2006 Public comment review meeting – January 15-17, 2007 2nd Public Comment Draft Posted for public comment – February 27, 2007 Public comment closed – March 26, 2006 Posting to ANSI Standards Action Public Posting – April 2007 Public comment review meeting – August 2007 (TBD) All public drafts, meeting notices (open to public), agendas and minutes posted on ICC web site Anticipated release date of January 2008 for ICC-500 www.iccsafe.org/cs/standards/is-stm Questions for ICC:  Questions for ICC David Bowman - Manager of Codes International Code Council (ICC) Chicago District Office 4051 W. Flossmoor Rd. Country Club Hills, IL 60478 Ph: 888-422-7233 x4323 Fax: 708-799-0320 [email protected] Next Meeting – August 2007 !!!! Additional Discussion Points and Supplemental Information:  Additional Discussion Points and Supplemental Information Storm Shelter Committee Members:  Storm Shelter Committee Members Building Code Officials Emergency Planning Managers Federal (FEMA) and State Officials Industry NAHB, NSSA, PCA, NCMA, AISI, Ingersoll Rand University faculty members: LSU, Texas Tech, Clemson Consultants URS, ARA, PBA, DuPont Status:  Status First committee meeting (May 2003) Gather input from scientific, technical, and user communities (ongoing) Develop draft standard and publish draft standard for public comment (November 15, 2006 through December 26, 2006) Formal, public committee meeting to address all comments January 15-18, 2007 Publish standard (est. mid 2007) ‘Type’ of Exposure B Important:  ‘Type’ of Exposure B Important Example of pre-storm Exposure B, becoming Exposure C during storm:  Example of pre-storm Exposure B, becoming Exposure C during storm Hurricane Andrew Kzt Topographic Factor:  Kzt Topographic Factor Accounts for speedup in wind near top of hills, ridges and escarpments Tornado Shelter Kzt = 1.0 Effects of topography on tornado windspeeds are unknown Hurricane Shelter Per ASCE 7-05 Kd Directionality Factor:  Kd Directionality Factor Accounts for reduced probability of maximum wind speed occurring simultaneously with most vulnerable wind direction ASCE 7-05 Kd = 0.85 IS-STM Hurricane and Tornado Shelter Kd = 1.0 Changing wind direction may bring maximum or near maximum wind speeds over a wide range of wind directions I Importance Factor:  I Importance Factor Accounts for change in MRI based on relative level of hazard to human life ASCE 7-05 I = 1.15 for shelters IS-STM Hurricane and Tornado Shelter I = 1.0 Already using an ‘ultimate’ wind speed with long mean recurrence interval Other Debris Hazards:  Other Debris Hazards Rollover hazards Laydown hazards Collapse hazards Siting requirements to minimize these hazards If they are present, must design for impacts Essential Features & Accessories:  Essential Features & Accessories Tornado Shelters Natural Ventilation req’d Ventilation and internal pressure relief may be designed concurrently Two options based on NSSA standard; above ground and below ground cases Outside air intakes to be located 10 ft from noxious contaminant sources Exhaust or intake openings to be protected More detailed than FEMA 361 Essential Features & Accessories:  Essential Features & Accessories Tornado Shelters Back-up or emergency gen-sets not required Emergency lighting req’d; avg=1 f.c. Exceptions for small shelters and 1&2 family dwellings; one flashlight per 10 occupants Plumbing/Sanitation Toilet fixtures: up to 50=1; 51-500=2; then 1 add’l:500 Temporary fixtures acceptable Exception for 1&2 Family Dwellings Handwashing facilities not req’d for small; 1:1000 for large Codifying FEMA 361 criteria Essential Features & Accessories:  Essential Features & Accessories Tornado Shelters Plumbing/Water No potable or waste water reqm’ts for either large or small shelters First-aid kit req’d for small and large shelters Exception for 1&2 Family Dwellings References Documents:  References Documents NSSA Industry Standard: Standard for the Design, Construction, and Performance of Storm Shelters FEMA 320: Taking Shelter from the Storm FEMA 361: Design and Construction Guidance for Community Shelters ARC 4496: Guidelines for Hurricane Evacuation Shelter Selection Florida Building Code - Enhanced Hurricane Protection Areas (EHPA), Section 423.25 FL DCA Statewide Emergency Shelter Plan Information Sources:  Information Sources Design & Construction Guidance for Community Shelters (FEMA 361) Taking Shelter from the Storm: Building a Safe Room inside your House (FEMA 320) National Storm Shelter Association Standard (NSSA 4000-02) Florida’s Public Shelter Design Criteria (section 423.25, Florida Building Code) Information Sources:  Information Sources MASS CARE—Management and Operations (ARC 3041) International Code Council (ICC) Codes Various FEMA, ARC and FBC publications and provisions

Related presentations


Other presentations created by Jolene

Smart Dust and Micro Robots
07. 01. 2008
0 views

Smart Dust and Micro Robots

2509 9h20 kessler usoinseguro
02. 05. 2008
0 views

2509 9h20 kessler usoinseguro

whats driving emerging markets
27. 09. 2007
0 views

whats driving emerging markets

Barrie Peter Pan Text Only
12. 10. 2007
0 views

Barrie Peter Pan Text Only

rutherford winterjohnson
13. 10. 2007
0 views

rutherford winterjohnson

chap3 2
16. 10. 2007
0 views

chap3 2

IntroDNACloningDNARep
16. 10. 2007
0 views

IntroDNACloningDNARep

MOAC204
17. 10. 2007
0 views

MOAC204

nile hydrology
23. 10. 2007
0 views

nile hydrology

12 HACCPJuiceSeafood French
24. 10. 2007
0 views

12 HACCPJuiceSeafood French

politiques Sant Boi Pere Dorca
24. 10. 2007
0 views

politiques Sant Boi Pere Dorca

thomson
15. 10. 2007
0 views

thomson

climate change and poverty
29. 11. 2007
0 views

climate change and poverty

botnet underground economics
04. 12. 2007
0 views

botnet underground economics

Macroevolution
12. 10. 2007
0 views

Macroevolution

Roman Religion powerpoint
29. 10. 2007
0 views

Roman Religion powerpoint

2268Atakan
31. 10. 2007
0 views

2268Atakan

Banned Books
31. 10. 2007
0 views

Banned Books

Bob
01. 11. 2007
0 views

Bob

Week 3 DW Design Kimball
07. 11. 2007
0 views

Week 3 DW Design Kimball

STILLEHAVSKRIGEN3
13. 11. 2007
0 views

STILLEHAVSKRIGEN3

enhancing osh standards
14. 11. 2007
0 views

enhancing osh standards

ELISA 2004
12. 10. 2007
0 views

ELISA 2004

Climate McBean f
21. 10. 2007
0 views

Climate McBean f

PP 08 Conditioning
16. 11. 2007
0 views

PP 08 Conditioning

Ontologies in Bioinformatics
20. 11. 2007
0 views

Ontologies in Bioinformatics

laminas centroamÃrica
22. 10. 2007
0 views

laminas centroamÃrica

1World War II
23. 12. 2007
0 views

1World War II

NOAA Fisheries NMFS
28. 12. 2007
0 views

NOAA Fisheries NMFS

ClassDay4
31. 12. 2007
0 views

ClassDay4

ENGR310 1 07
03. 01. 2008
0 views

ENGR310 1 07

PAN Villarreal
22. 10. 2007
0 views

PAN Villarreal

gpr
05. 01. 2008
0 views

gpr

hansen
29. 10. 2007
0 views

hansen

3 El Hattab Ahamed
25. 10. 2007
0 views

3 El Hattab Ahamed

marrocos2
24. 10. 2007
0 views

marrocos2

NWS Partnering
05. 10. 2007
0 views

NWS Partnering

Lyster
16. 10. 2007
0 views

Lyster

webcast1
29. 10. 2007
0 views

webcast1

Chicago
15. 10. 2007
0 views

Chicago

Faridah Noor Indian Dance New
23. 11. 2007
0 views

Faridah Noor Indian Dance New

xmm UG 051606
28. 11. 2007
0 views

xmm UG 051606

ISOM7
15. 10. 2007
0 views

ISOM7

Thermocouple
16. 02. 2008
0 views

Thermocouple

Gubler
21. 10. 2007
0 views

Gubler

test5
30. 10. 2007
0 views

test5

pit 2
26. 02. 2008
0 views

pit 2

m6 Eyler
28. 02. 2008
0 views

m6 Eyler

PSCM
07. 03. 2008
0 views

PSCM

pfl powerpoint may06
10. 03. 2008
0 views

pfl powerpoint may06

Prasa2001
13. 03. 2008
0 views

Prasa2001

PresentationANALYSTE SSNI2006
24. 10. 2007
0 views

PresentationANALYSTE SSNI2006

Perine I2 22april04
16. 03. 2008
0 views

Perine I2 22april04

Panel B Igor Hansen
20. 03. 2008
0 views

Panel B Igor Hansen

kapil kaul
25. 03. 2008
0 views

kapil kaul

part1 intro
07. 10. 2007
0 views

part1 intro

ans1 ffa program
03. 04. 2008
0 views

ans1 ffa program

Jonah
07. 04. 2008
0 views

Jonah

051208 Osawa
09. 10. 2007
0 views

051208 Osawa

3arq
18. 10. 2007
0 views

3arq

Bourgeat Siam
06. 12. 2007
0 views

Bourgeat Siam

allen
08. 04. 2008
0 views

allen

Fry 2005
10. 04. 2008
0 views

Fry 2005

ValueofNonpartisan
14. 04. 2008
0 views

ValueofNonpartisan

lovelock12
16. 04. 2008
0 views

lovelock12

Pumpkin SmallSat 2006
17. 04. 2008
0 views

Pumpkin SmallSat 2006

CSAM DOJ Briefing Day2
22. 04. 2008
0 views

CSAM DOJ Briefing Day2

SOUTHEAST pp
03. 01. 2008
0 views

SOUTHEAST pp

Arbetslagsplan 04 05
02. 11. 2007
0 views

Arbetslagsplan 04 05

dentist
06. 05. 2008
0 views

dentist

critical care slides
07. 05. 2008
0 views

critical care slides

origins
08. 05. 2008
0 views

origins

mas info
08. 05. 2008
0 views

mas info

18 4
22. 10. 2007
0 views

18 4

Vulvodynia
01. 05. 2008
0 views

Vulvodynia

014 Robot Control Architectures
02. 05. 2008
0 views

014 Robot Control Architectures

3678s1 03 schechter
02. 05. 2008
0 views

3678s1 03 schechter

Dana Guerrieri
02. 05. 2008
0 views

Dana Guerrieri

Anestezja
02. 05. 2008
0 views

Anestezja

lezersp1
15. 10. 2007
0 views

lezersp1

20050928 Yasuyuki Fuchita
09. 10. 2007
0 views

20050928 Yasuyuki Fuchita

S Pathi
16. 10. 2007
0 views

S Pathi

Thompson Adjusted
30. 04. 2008
0 views

Thompson Adjusted

Poretti dscut Gdor CW8
15. 11. 2007
0 views

Poretti dscut Gdor CW8

2002 04 maintenance
19. 11. 2007
0 views

2002 04 maintenance

N1 Richard News from ELAN Paris
29. 09. 2007
0 views

N1 Richard News from ELAN Paris

cal20050303
09. 10. 2007
0 views

cal20050303

TUD About the institution
18. 03. 2008
0 views

TUD About the institution

iPOP2007 OIF Berthold
09. 10. 2007
0 views

iPOP2007 OIF Berthold

patricia arsene
15. 10. 2007
0 views

patricia arsene

IHS 2003
27. 03. 2008
0 views

IHS 2003

MOTIVATE 1 slides
29. 10. 2007
0 views

MOTIVATE 1 slides

Alia2003
05. 10. 2007
0 views

Alia2003

RE SUNUM ppt2
23. 11. 2007
0 views

RE SUNUM ppt2

grid2000 welcome
17. 10. 2007
0 views

grid2000 welcome

Larry
07. 01. 2008
0 views

Larry

Abel
25. 10. 2007
0 views

Abel

Weitz Tracy 1 24 07
03. 01. 2008
0 views

Weitz Tracy 1 24 07

del rel
07. 11. 2007
0 views

del rel

ilc analyse
23. 10. 2007
0 views

ilc analyse

CAS 07 MDHS
02. 05. 2008
0 views

CAS 07 MDHS