Anes Equip Probs 03

Information about Anes Equip Probs 03

Published on April 30, 2008

Author: Melinda

Source: authorstream.com

Content

New and Old Problems with Anesthesia Equipment BWH Anesthesia Grand Rounds July 9, 2003:  New and Old Problems with Anesthesia Equipment BWH Anesthesia Grand Rounds July 9, 2003 © Copyright 2002-2003, James H Philip, All rights reserved. Slide2:  Equip Probs JHP Ready If you stay you will learn how and why the following are true:  If you stay you will learn how and why the following are true Suction can fail 11 different ways There are many ways a vaporizer can fail O-rings cause many failures New Tec7 vaporizer needs special filler adapter and must be pressed to fill Checkout includes Ventilator Checkout includes “Admit Patient” to reset alarms Use an HME to keep the circuit dry and ventilator and gas sampling working Gas Sample Filters are cracking. Save all that crack to be sent to Manufacturer Free-hosing with Forced Hot Air (e.g., Bair Hugger) is dangerous - don’t do it Draeger Fabius moos and can have negative (sucking) leaks A shorter checkout is possible - Should we post it? Should we do it? ECG Filter must not be set to Maximum if want to monitor S-T, T waves Problem Solving - Clinical vs Technical; Treat signs; Find & Treat Root Cause Block on: Problem Solving in Anesthesia:  Block on: Problem Solving in Anesthesia July 9, 2003 7 - 8 AM New & Old Problems with Anesthesia Equipment James Philip, M.D. 8 - 9 AM Hypotension George Topulos, M.D. New and Old Problems with Anesthesia Equipment James H. Philip MEE MD CCE Anesthesiologist Medical Liaison for Partners Biomedical Engineering Director of Technology Assessment for BWH:  New and Old Problems with Anesthesia Equipment James H. Philip MEE MD CCE Anesthesiologist Medical Liaison for Partners Biomedical Engineering Director of Technology Assessment for BWH Biomed Intro:  Biomed Intro Failed Suction :  Failed Suction Patient is a 29 yo F receiving general anesthesia for elective gynecologic surgery. Immediately after loss of consciousness, the patient vomits You place the Yankauer Suction in patient’s mouth and occlude the vent hole But, nothing happens What is going on? Suction can fail in many ways:  Suction can fail in many ways DISS (Diameter Index Safety System) Connector Unscrewed at Wall Suction can fail in many ways:  Suction can fail in many ways DISS (Diameter Index Safety System) Connector Unscrewed at Wall Vacuum Switched Off at DISS Connector Canister problem:  Canister problem Hose disconnect from canister Canister switched off Insert seated incorrectly Any port or hole open Hose disconnect from holder Tubing disconnect from canister Flap valve closed Canister Tilted Canister Full Hose kinked Suction Solution:  Suction Solution Test Function Before Case During Case New Vaporizers have New Failure Modes:  New Vaporizers have New Failure Modes Tec7 Vaporizer by Datex-Ohmeda:  Tec7 Vaporizer by Datex-Ohmeda Differences from previous White, not black Still Agent-specific for: Halothane, Enflurane, Isoflurane, Sevoflurane Wider flow range = .2 L - 15 LPM Non-spill system limits movement of liquid if tilted or inverted No periodic service required ( Tec 4 = 1 yr, Tec 5 = 3 yr, Tec 7 no) Easy-fil™ System 50% faster fill than previous (Tec 3,4,5) Low-leak fill Intuitive alignment (they say) Soldered sump and seal (not O-rings) Easy Fil™:  Easy Fil™ No Spill Auto Fill ? Press to overcome spring No Which is filling as we watch?:  Which is filling as we watch? Desflurane Tec6 Semi-Automatic Fill (no patent pending) Why no O-rings?:  Why no O-rings? O-rings fail Space Shuttle Forreger Anesthesia Machines O-Rings sealed a three-vaporizer turret Failed during drug administration Simultaneous delivery of multiple overdoses Last product Forreger ever made Desflurane bottle fill The O Ring belongs here:  The O Ring belongs here The O-Ring is missing:  The O-Ring is missing This is filling with no O-ring:  This is filling with no O-ring When you change a vaporizer:  When you change a vaporizer When you change a vaporizer:  When you change a vaporizer You are expected to do a Negative Pressure Leak Test [See FDA Pre-Use Check Card attached to every Anesthesia Machine] Negative Pressure Leak Test:  Negative Pressure Leak Test Negative Pressure Bulb is in Drawer:  Negative Pressure Bulb is in Drawer If not, Page your Anes Tech Condensed water vapor :  Condensed water vapor Makes Ventilators fail Makes Gas Monitors fail Use a Heat and Moisture Exchanger Wet dome valve - Ohmeda Mod 2:  Wet dome valve - Ohmeda Mod 2 Wet dome valve - Aestiva:  Wet dome valve - Aestiva Fabius flow sensor gets wet, too:  Fabius flow sensor gets wet, too Wet ET tube, dry circuit:  Wet ET tube, dry circuit Datex-Ohmeda Edith® is BWH present HME product:  Datex-Ohmeda Edith® is BWH present HME product Gas Line Filters sometimes crack:  Gas Line Filters sometimes crack Save them if they do crack Page Anes Technician who will bring it to ORCSS Materials Management” to return to Manufacturer For analysis Forced Hot Air warming:  Forced Hot Air warming Use a Blanket Do not use hose without Blanket FDA, ECRI, Manufacturers are appropriately concerned Blanket costs around $10.00 This is not the right place to save money Fabius idiosynchrocies:  Fabius idiosynchrocies Moos like Cow Temporary problem which will be solved If reservoir bag is empty or has a leak Air will be drawn into breathing circuit during mechanical ventilation Anesthesia Machine Checkout:  Anesthesia Machine Checkout Important Will pick up many problems Common root cause of mishap is: Failure to Pre-Check Equipment Check Ventilator Function as part of Check Out:  Check Ventilator Function as part of Check Out Ventilate reservoir bag Observe no volume loss Added recently to our list Admit “New Patient” or re-boot Monitor and Ventilator:  Admit “New Patient” or re-boot Monitor and Ventilator Returns alarms and configuration to Site-Standard Settings (BWH) Failure to do this has led to several reported “events” Added recently to our list Placard on every Anes Machine:  Placard on every Anes Machine Should we also post abbreviated checkout? Abbreviated Machine Check Out:  Abbreviated Machine Check Out Calibrate Oxygen Monitor Check Machine for gas delivery Check Circuit for integrity Check Ventilator for function Check Exhaust for function ECG Monitor filter must not be set to Maximum:  ECG Monitor filter must not be set to Maximum Monitor offers several bandwidth options All faithfully convey ST and T waves except Maximum Filter This keeps wave on screen but Distorts S-T segment and T waves ST and T are “low frequency” “Maximum” filter removes (ruins) these Bandwidth Definitions Diagnostic = .05 - 120 Hz Monitoring = .05 - 40 Hz Moderate = .05 - 25 Hz Maximum = .5 - 25 Hz - the only really bad one Troubleshooting a “Clinical” Problem:  Troubleshooting a “Clinical” Problem Phase 1 – Patient or Equipment Problem ? This differentiation is crucial Starting on the wrong track is a bad start Phase 2 – Treat Signs and seek Root Cause Phase 3 – Treat or correct Root Cause Slide40:  Thank you If you stayed you learned how and why the following are true:  If you stayed you learned how and why the following are true Suction can fail 11 different ways There are many ways a vaporizer can fail O-rings cause many failures New Tec7 vaporizer needs special filler adapter and must be pressed to fill Checkout includes Ventilator Checkout includes “Admit Patient” to reset alarms Use an HME to keep the circuit dry and ventilator and gas sampling working Gas Sample Filters are cracking. Save all that crack to be sent to Manufacturer Free-hosing with Forced Hot Air (e.g., Bair Hugger) is dangerous - don’t do it Draeger Fabius moos and can have negative (sucking) leaks A shorter checkout is possible - Should we post it? Should we do it? ECG Filter must not be set to Maximum if want to monitor S-T, T waves Problem Solving - Clinical vs Technical; Treat signs; Find & Treat Root Cause Requests from Anes Dept:  Requests from Anes Dept Negative Pressure tester in each room Techs do the negative pressure test when they change Vap Techs do circuit pressure test when they connect circuit Aquanaut in OR where used - likely Anes Machine Drawer 5% Sevo alarm default on RGM - Increase it if possible End Here:  End Here New Resources - on Anes Server or CD:  New Resources - on Anes Server or CD From Anesthesia Clinical Bioengineering Elective Residents Brain Monitor Physiometrix PSA4000 - Maurizio Albala MD Brain Monitor Aspect BIS - Maurizio Albala MD GE (Marquette) 9500 Monitor - John Cabral MD Ohmeda RGM Monitor - Jason Ryan MD Ohmeda Tec5 Vaporizer in pieces at Sea Level & Altitude Jason Ryan MD Aestiva Check-Out - Morana Lasic MD Ventilators - Sascha Beutler MD Respiratory Mechanics Module - Eveline Ehrl MD Gas Sampling systems - Jasline Dhingra MD Slide46:  End Slide47:  Whom to Ask James H. Philip, MEE, MD Anesthesiologist and Director of Bioengineering (Anesthesia) Office PBBH - B Ground 732-7330 BB1615) [email protected] Slide48:  End

Related presentations


Other presentations created by Melinda

MOLLUSCA Power Point
20. 02. 2008
0 views

MOLLUSCA Power Point

using physician extenders
08. 05. 2008
0 views

using physician extenders

Consumer s Rights
07. 05. 2008
0 views

Consumer s Rights

spscicomp6
02. 05. 2008
0 views

spscicomp6

Energy1
02. 05. 2008
0 views

Energy1

FML2004 1
02. 05. 2008
0 views

FML2004 1

Roberta Zobbi
02. 05. 2008
0 views

Roberta Zobbi

Brain Cancer Causes
02. 05. 2008
0 views

Brain Cancer Causes

Fin525Fall2006Week7
28. 04. 2008
0 views

Fin525Fall2006Week7

Keynote
22. 04. 2008
0 views

Keynote

Bonding
16. 02. 2008
0 views

Bonding

Systems Analysis Presentation
06. 03. 2008
0 views

Systems Analysis Presentation

BizRetPresentation Final
01. 10. 2007
0 views

BizRetPresentation Final

9 Oyieke Illicit Trade
10. 10. 2007
0 views

9 Oyieke Illicit Trade

Khosla Biofuels GEC DC 3 1 06
15. 10. 2007
0 views

Khosla Biofuels GEC DC 3 1 06

28 Thermal Baths at Vals
19. 10. 2007
0 views

28 Thermal Baths at Vals

pk momterrey 11 04
21. 10. 2007
0 views

pk momterrey 11 04

marie robinson
22. 10. 2007
0 views

marie robinson

OceanStore tahoe2
07. 10. 2007
0 views

OceanStore tahoe2

gis in health
23. 10. 2007
0 views

gis in health

Spalart SanFran 06
30. 10. 2007
0 views

Spalart SanFran 06

W Simpson Foresman
02. 11. 2007
0 views

W Simpson Foresman

transitioning
07. 11. 2007
0 views

transitioning

Lopez Cerezo y Lujan
22. 10. 2007
0 views

Lopez Cerezo y Lujan

024
25. 10. 2007
0 views

024

qiao
15. 11. 2007
0 views

qiao

Skills for Life2
19. 11. 2007
0 views

Skills for Life2

Dr Painter Food Psychology
22. 10. 2007
0 views

Dr Painter Food Psychology

MIE2006 RIDE
29. 10. 2007
0 views

MIE2006 RIDE

thesaurus 1
04. 12. 2007
0 views

thesaurus 1

burns pp
04. 01. 2008
0 views

burns pp

rubrics
01. 01. 2008
0 views

rubrics

IZ 101 Slides Revision
30. 10. 2007
0 views

IZ 101 Slides Revision

midterm review
02. 11. 2007
0 views

midterm review

Armstrong
03. 01. 2008
0 views

Armstrong

Mr KONDO Presentation 070603
09. 10. 2007
0 views

Mr KONDO Presentation 070603

dossier de presse
24. 10. 2007
0 views

dossier de presse

pres clarkm5
15. 10. 2007
0 views

pres clarkm5

Joe Caddell ppt
24. 10. 2007
0 views

Joe Caddell ppt

Slivovsky CPE350 Lecture1
31. 12. 2007
0 views

Slivovsky CPE350 Lecture1

materiasprimas
04. 10. 2007
0 views

materiasprimas

swords
26. 02. 2008
0 views

swords

capstone designing
31. 10. 2007
0 views

capstone designing

03 Basic Chemistry
04. 03. 2008
0 views

03 Basic Chemistry

Contraception
12. 10. 2007
0 views

Contraception

P Letardi
01. 11. 2007
0 views

P Letardi

NUR lecture 2
07. 01. 2008
0 views

NUR lecture 2

Global Health
11. 03. 2008
0 views

Global Health

Solar5
07. 04. 2008
0 views

Solar5

Gumbert vormittags
29. 12. 2007
0 views

Gumbert vormittags

35
22. 10. 2007
0 views

35

STB OrgChart 050819
25. 03. 2008
0 views

STB OrgChart 050819

wf conf june5
09. 04. 2008
0 views

wf conf june5

global nondeal roadshow
11. 04. 2008
0 views

global nondeal roadshow

L04 dg c2
10. 12. 2007
0 views

L04 dg c2

20 Non renewables
16. 04. 2008
0 views

20 Non renewables

SAINSEL Kickoff
23. 10. 2007
0 views

SAINSEL Kickoff

Futures Pricing and Strategies
17. 04. 2008
0 views

Futures Pricing and Strategies

tutorial avedon
24. 02. 2008
0 views

tutorial avedon

k waldron avnwx tdas
07. 03. 2008
0 views

k waldron avnwx tdas

ASPO2005 Leonard
12. 10. 2007
0 views

ASPO2005 Leonard

powerpointmba
16. 11. 2007
0 views

powerpointmba

marxfam2
19. 02. 2008
0 views

marxfam2

antihistamines 2006
16. 10. 2007
0 views

antihistamines 2006

CD San Francisco 11 14
29. 10. 2007
0 views

CD San Francisco 11 14

russian transportation
11. 10. 2007
0 views

russian transportation

ibcoldwar
08. 04. 2008
0 views

ibcoldwar

Agrimi Workshop7 THC5
17. 10. 2007
0 views

Agrimi Workshop7 THC5

Pompey the Great
03. 04. 2008
0 views

Pompey the Great

wipo smes sin 07 8 parta
28. 02. 2008
0 views

wipo smes sin 07 8 parta

P1Slides
17. 10. 2007
0 views

P1Slides

JubbDinner Keynote
07. 01. 2008
0 views

JubbDinner Keynote

old china new japan
09. 10. 2007
0 views

old china new japan

Paul Browne Selected MSc Work
29. 09. 2007
0 views

Paul Browne Selected MSc Work

ppt simons
13. 11. 2007
0 views

ppt simons

Bucharest Denisov
11. 10. 2007
0 views

Bucharest Denisov

Huettner QA systems 00 04 11
16. 10. 2007
0 views

Huettner QA systems 00 04 11

4941
13. 04. 2008
0 views

4941

Lucy
05. 01. 2008
0 views

Lucy